KEYENCE EV-EZ Ayarlanabilir Algılama Hassasiyetli Endüktif Sensörler

Özellikler
- Küçük ve kısa sensör boyutları
- Sensöre entegre edilmiş çıkış göstergesi
- Harekete dayanımlı esnek kablo
- IP67 standardı ile uyumlu gövde
Avantajlar
Küçük boyutları ve hareketli proseslere uygun kablosu ile, standartların üzerinde algılama kararlılığı sunar.
- EV-108M
- EV-108UC
- EV-112F
- EV-112M
- EV-112MC
- EV-112U
- EV-118F
- EV-118M
- EV-118MC
- EV-118U
- EV-130M (5000)
- EV-130UC
- EZ-12M
- EZ-18M
- EZ-18T
- EZ-8M
Model |
EV-108M |
|||
type |
Direct current (DC) shield type (can be embedded in metal) |
|||
shape |
M8 screw type |
|||
Detection distance |
1.5mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
10 x 10 mm |
|||
Spacing distance |
10% or less of the detection distance |
|||
Response frequency |
800Hz |
|||
Operation mode |
NO |
|||
Temperature characteristics |
Within ± 10% of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output (open / close capacity) |
5-80mA |
|||
Protection circuit |
Reverse connection protection / surge absorption |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
500 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
SUS304 |
|||
accessories |
Nut x 2 Toothed washer x 1 Instruction manual |
|||
mass |
Approximately 42 g (with nut cord 2 m) |
Model |
EV-108UC |
|||
type |
Direct current (DC) unshielded type |
|||
shape |
M8 screw type |
|||
Detection distance |
4.0mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
20 x 20 mm |
|||
Spacing distance |
20% or less of the detection distance (-10 to + 70 ° C) |
|||
Response frequency |
800Hz |
|||
Operation mode |
NC |
|||
Temperature characteristics |
Within ± 10% of the detection distance at + 23 ° C (-10 to + 70 ° C) |
|||
Control output (open / close capacity) |
5-80mA |
|||
Protection circuit |
Reverse connection protection / surge absorption |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
500 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
SUS304 |
|||
accessories |
Nut x 2 Toothed washer x 1 Instruction manual |
|||
mass |
Approximately 42 g (with nut cord 2 m) |
Model |
EV-112F |
|||
type |
Shield type (can be embedded in metal) |
|||
shape |
M12 screw type |
|||
Detection distance |
2.5 mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
12 x 12 mm |
|||
Spacing distance |
15% or less of the detection distance |
|||
Response frequency |
600Hz |
|||
Operation mode |
NO |
|||
Temperature characteristics |
Within ± 10% of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output (open / close capacity) |
5 to 200 mA |
|||
Protection circuit |
Reverse connection protection, surge absorption, short circuit protection |
|||
cable length |
2 m |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
500 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Fluororesin coating * 1 |
|||
accessories |
Nut x 2, toothed washer x 1 |
|||
mass |
Approximately 110 g (with nut cord 2 m) |
|||
* 1 Chemical resistance is the same as the standard type that is not coated with fluororesin. |
Model |
EV-112M |
|||
type |
Direct current (DC) shield type (can be embedded in metal) |
|||
shape |
M12 screw type |
|||
Detection distance |
2.5mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
12 x 12 mm |
|||
Spacing distance |
10% or less of the detection distance |
|||
Response frequency |
600Hz |
|||
Operation mode |
NO |
|||
Temperature characteristics |
Within ± 10% of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output (open / close capacity) |
5 to 200mA |
|||
Protection circuit |
Reverse connection protection, surge absorption, short circuit protection |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
500 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Nickel plating |
|||
accessories |
Nut x 2 Toothed washer x 1 Instruction manual |
|||
mass |
Approximately 110 g (with nut cord 2 m) |
Model |
EV-112MC |
|||
type |
Direct current (DC) shield type (can be embedded in metal) |
|||
shape |
M12 screw type |
|||
Detection distance |
2.5mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
12 x 12 mm |
|||
Spacing distance |
10% or less of the detection distance |
|||
Response frequency |
600Hz |
|||
Operation mode |
NC |
|||
Temperature characteristics |
Within ± 10% of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output (open / close capacity) |
5 to 200mA |
|||
Protection circuit |
Reverse connection protection, surge absorption, short circuit protection |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
500 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Nickel plating |
|||
accessories |
Nut x 2 Toothed washer x 1 Instruction manual |
|||
mass |
Approximately 110 g (with nut cord 2 m) |
Model |
EV-112U |
|||
type |
Direct current (DC) unshielded type |
|||
shape |
M12 screw type |
|||
Detection distance |
8.0mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
30 x 30 mm |
|||
Spacing distance |
20% or less of the detection distance (-10 to + 70 ° C) |
|||
Response frequency |
600Hz |
|||
Operation mode |
NO |
|||
Temperature characteristics |
Within ± 10% of the detection distance at + 23 ° C (-10 to + 70 ° C) |
|||
Control output (open / close capacity) |
5 to 200mA |
|||
Protection circuit |
Reverse connection protection, surge absorption, short circuit protection |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
500 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Nickel plating |
|||
accessories |
Nut x 2 Toothed washer x 1 Instruction manual |
|||
mass |
Approximately 110 g (with nut cord 2 m) |
Model |
EV-118F |
|||
type |
Shield type (can be embedded in metal) |
|||
shape |
M18 screw type |
|||
Detection distance |
5.0 mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
18 x 18 mm |
|||
Spacing distance |
15% or less of the detection distance |
|||
Response frequency |
350Hz |
|||
Operation mode |
NO |
|||
Temperature characteristics |
Within ± 10% of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output (open / close capacity) |
5 to 200 mA |
|||
Protection circuit |
Reverse connection protection, surge absorption, short circuit protection |
|||
cable length |
2 m |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
1,000 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Fluororesin coating * 1 |
|||
accessories |
Nut x 2, toothed washer x 1 |
|||
mass |
Approximately 150 g (with nut cord 2 m) |
|||
* 1 Chemical resistance is the same as the standard type that is not coated with fluororesin. |
Model |
EV-118M |
|||
type |
Direct current (DC) shield type (can be embedded in metal) |
|||
shape |
M18 screw type |
|||
Detection distance |
5.0mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
18 x 18 mm |
|||
Spacing distance |
10% or less of the detection distance |
|||
Response frequency |
350Hz |
|||
Operation mode |
NO |
|||
Temperature characteristics |
Within ± 10% of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output (open / close capacity) |
5 to 200mA |
|||
Protection circuit |
Reverse connection protection, surge absorption, short circuit protection |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
1,000 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Nickel plating |
|||
accessories |
Nut x 2 Toothed washer x 1 Instruction manual |
|||
mass |
Approximately 150 g (with nut cord 2 m) |
Model |
EV-118MC |
|||
type |
Direct current (DC) shield type (can be embedded in metal) |
|||
shape |
M18 screw type |
|||
Detection distance |
5.0mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
18 x 18 mm |
|||
Spacing distance |
10% or less of the detection distance |
|||
Response frequency |
350Hz |
|||
Operation mode |
NC |
|||
Temperature characteristics |
Within ± 10% of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output (open / close capacity) |
5 to 200mA |
|||
Protection circuit |
Reverse connection protection, surge absorption, short circuit protection |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
1,000 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Nickel plating |
|||
accessories |
Nut x 2 Toothed washer x 1 Instruction manual |
|||
mass |
Approximately 150 g (with nut cord 2 m) |
Model |
EV-118U |
|||
type |
Direct current (DC) unshielded type |
|||
shape |
M18 screw type |
|||
Detection distance |
15.0mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
50 x 50 mm |
|||
Spacing distance |
20% or less of the detection distance (-10 to + 70 ° C) |
|||
Response frequency |
350Hz |
|||
Operation mode |
NO |
|||
Temperature characteristics |
Within ± 10% of the detection distance at + 23 ° C (-10 to + 70 ° C) |
|||
Control output (open / close capacity) |
5 to 200mA |
|||
Protection circuit |
Reverse connection protection, surge absorption, short circuit protection |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
1,000 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Nickel plating |
|||
accessories |
Nut x 2 Toothed washer x 1 Instruction manual |
|||
mass |
Approximately 140 g (with nut cord 2 m) |
Model |
EV-130M |
|||
type |
Direct current (DC) shield type (can be embedded in metal) |
|||
shape |
M30 screw type |
|||
Detection distance |
10.0mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
30 x 30 mm |
|||
Spacing distance |
10% or less of the detection distance |
|||
Response frequency |
250Hz |
|||
Operation mode |
NO |
|||
Temperature characteristics |
Within ± 10% of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output (open / close capacity) |
5 to 200mA |
|||
Protection circuit |
Reverse connection protection, surge absorption, short circuit protection |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
1,000 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Nickel plating |
|||
accessories |
Nut x 2 Toothed washer x 1 Instruction manual |
|||
mass |
Approximately 300 g (with nut cord 2 m) |
Model |
EV-130UC |
|||
type |
Direct current (DC) unshielded type |
|||
shape |
M30 screw type |
|||
Detection distance |
27.0mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1 mm) |
70 x 70 mm |
|||
Spacing distance |
20% or less of the detection distance (-10 to + 70 ° C) |
|||
Response frequency |
250Hz |
|||
Operation mode |
NC |
|||
Temperature characteristics |
Within -5% to + 20% (-10 to + 70 ° C) |
|||
Control output (open / close capacity) |
5 to 200mA |
|||
Protection circuit |
Reverse connection protection, surge absorption, short circuit protection |
|||
Rated |
Power-supply voltage |
DC 12-24 V, Ripple (PP) 20% or less |
||
Consumed (leakage) current |
1.0mA or less |
|||
Residual voltage |
3.6V or less (at cord length 2m) |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
1,000 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Nickel plating |
|||
accessories |
Nut x 2 Toothed washer x 1 Instruction manual |
|||
mass |
Approximately 260 g (with nut cord 2 m) |
Model |
EZ-12M |
|||
type |
Shield type (can be embedded in metal) Screw type |
|||
shape |
M12 |
|||
Detection distance |
2.5 mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1mm) |
12 x 12 mm |
|||
Spacing distance |
10% or less of the detection distance |
|||
Response frequency |
600Hz |
|||
Operation mode |
Both NO / NC output |
|||
Temperature characteristics |
± 10% or less of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output |
NPN open collector Maximum 100mA (40V or less) Residual voltage 1V or less |
|||
cable length |
2 m |
|||
Rated |
Power-supply voltage |
DC 12-24 V ± 10%, Ripple (PP) 10% or less |
||
Current consumption |
13 mA or less |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
500 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Nickel plating |
|||
accessories |
Nut x 2, toothed washer x 1 |
|||
mass |
Approximately 65 g (with nut cord 2 m) |
Model |
EZ-18M |
|||
type |
Shield type (can be embedded in metal) Screw type |
|||
shape |
M18 |
|||
Detection distance |
5.0 mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1mm) |
18 x 18 mm |
|||
Spacing distance |
10% or less of the detection distance |
|||
Response frequency |
350Hz |
|||
Operation mode |
Both NO / NC output |
|||
Temperature characteristics |
± 10% or less of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output |
NPN open collector Maximum 100mA (40V or less) Residual voltage 1V or less |
|||
cable length |
2 m |
|||
Rated |
Power-supply voltage |
DC 12-24 V ± 10%, Ripple (PP) 10% or less |
||
Current consumption |
13 mA or less |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
1,000 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Nickel plating |
|||
accessories |
Nut x 2, toothed washer x 1 |
|||
mass |
Approximately 130 g (with nut cord 2 m) |
Model |
EZ-18T |
|||
type |
Shield type (can be embedded in metal) Thin |
|||
shape |
20 x 32 x 8 mm |
|||
Detection distance |
5.0 mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1mm) |
18 x 18 mm |
|||
Spacing distance |
10% or less of the detection distance |
|||
Response frequency |
350Hz |
|||
Operation mode |
Both NO / NC output |
|||
Temperature characteristics |
± 10% or less of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output |
NPN open collector Maximum 100mA (40V or less) Residual voltage 1V or less |
|||
cable length |
2 m |
|||
Rated |
Power-supply voltage |
DC 12-24 V ± 10%, Ripple (PP) 10% or less |
||
Current consumption |
13 mA or less |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
1,000 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
Aluminum die-cast |
|||
accessories |
Nut x 2, toothed washer x 1 |
|||
mass |
Approximately 55 g (with nut cord 2 m) |
Model |
EZ-8M |
|||
type |
Shield type (can be embedded in metal) Screw type |
|||
shape |
M8 |
|||
Detection distance |
1.5 mm ± 10% |
|||
Detected object |
Magnetic metal (Refer to the characteristic diagram for non-magnetic metal) |
|||
Standard detection object (iron t = 1mm) |
10 x 10 mm |
|||
Spacing distance |
10% or less of the detection distance |
|||
Response frequency |
800Hz |
|||
Operation mode |
Both NO / NC output |
|||
Temperature characteristics |
± 10% or less of the detection distance at + 23 ° C (-25 to + 70 ° C) |
|||
Control output |
NPN open collector Maximum 100mA (40V or less) Residual voltage 1V or less |
|||
cable length |
2 m |
|||
Rated |
Power-supply voltage |
DC 12-24 V ± 10%, Ripple (PP) 10% or less |
||
Current consumption |
13 mA or less |
|||
Environmental resistance |
Protective structure |
IP67 |
||
Operating ambient temperature |
-25 to + 80 ° C (do not freeze) |
|||
Operating ambient humidity |
35-95% RH (no condensation) |
|||
Vibration resistant |
10-55 Hz, double amplitude 1.5 mm, X, Y, Z 2 hours in each direction |
|||
Impact resistance |
500 m / s 2 , X, Y, Z 3 times in each direction |
|||
Case material |
SUS303 |
|||
accessories |
Nut x 2, toothed washer x 1 |
|||
mass |
Approximately 50 g (with nut cord 2 m) |